On 10/09/2026 I created a new app in Microsoft Entra ID for PnP PowerShell, ran Connect-PnPOnline -Interactive with its client ID. Instead of a working sign-in, the PnP login window said AADSTS500113: No reply address is registered for the application.
The cause is simple: the app had no redirect URI, so Entra ID had nowhere to send the token. Below I’ll show the fix with screenshots from my tenant, explain which redirect URI PnP PowerShell really needs, and cover device code sign-in and other tools.
Quick answer: Your app registration has no redirect URI. In the Microsoft Entra admin center, open Entra ID > App registrations > your app > Authentication > Redirect URI configuration > + Add Redirect URI > Mobile and desktop applications. Check the nativeclient URI, type http://localhost in the custom box, select Configure, and connect again.
What AADSTS500113 means
This is the command I ran:
Connect-PnPOnline -Url "https://contoso.sharepoint.com/sites/Marketing" `
-ClientId "00000000-0000-0000-0000-000000000000" -Interactive
And this is what the Please login for PnP PowerShell window showed, with the IDs trimmed:
Sorry, but we're having trouble signing you in.
AADSTS500113: No reply address is registered for the application.
Troubleshooting details
Request Id: <GUID>
Correlation Id: <GUID>
Timestamp: 2026-10-09T18:57:01Z
Message: AADSTS500113: No reply address is registered for the application.

A redirect URI (Microsoft’s older name is reply URL) is the address where Entra ID sends you and your token after sign-in. Entra ID only sends tokens to addresses listed on the app registration. My app had none, so the sign-in stopped right there.
You’ll usually hit this right after building your own app for PnP PowerShell, which has been required since September 2024. The New registration page leaves the Redirect URI field optional, and it’s easy to skip. My guide to connecting to SharePoint Online using PowerShell walks through the full app setup.
Keep the Correlation Id and Timestamp from the Troubleshooting details. An admin can match them to the failed entry in the Entra sign-in logs.
Which redirect URI does PnP PowerShell need?
My screenshots below check the suggested nativeclient URI, while PnP’s own setup guide says to add http://localhost. So I checked what PnP PowerShell actually sends:
- PnP PowerShell 3.x opens your default browser for
-Interactiveand asks Entra ID to return the token tohttp://localhoston a random free port. - PnP PowerShell 2.x on Windows showed the embedded Please login for PnP PowerShell window from my screenshot. It also used
http://localhostwith a random port. - Entra ID ignores the port on localhost redirect URIs, so one
http://localhostentry covers every port.
So http://localhost is the URI that matters. The nativeclient URI is Microsoft’s suggestion for apps with an embedded browser. It’s harmless, and PnP’s own registration cmdlet adds it too, but on its own it won’t match PnP’s request. You’d likely trade AADSTS500113 for AADSTS50011, the reply URL mismatch error.
| How you connect | What PnP sends | What to add to the app |
|---|---|---|
-Interactive | http://localhost:<port> | http://localhost under Mobile and desktop applications |
-OSLogin (Windows sign-in broker) | Broker redirect URI | ms-appx-web://microsoft.aad.brokerplugin/<client ID> |
-DeviceLogin | No redirect URI | Allow public client flows turned on |
How to fix AADSTS500113 in the Microsoft Entra admin center
You need to own the app registration or hold a role that manages app registrations, such as Application Administrator or Cloud Application Administrator.
Step 1. Sign in to the Microsoft Entra admin center and go to Entra ID > App registrations > All applications. Open the app whose Application (client) ID matches the -ClientId you passed to PnP.